11. Technical Data

Table 8

Description

Value

Remarks

Protective heights

120 mm to 1920mm

120mm increments

Operating range

0 ... 9 m

Resolution 14 mm

0 ...6m

Resolution 30 mm

Object detection capability

14 mm

(Resolution)

30 mm

Power supply U

sp

24 VDC ± 20 %

PELV, IEC 60 204-1

Power supply ripple

< 10 % of U

sp

Equipment Class

III

VDE 0106 part 100

Time for self check when switching on U

sp

< 3 s

Current consumption

< 500 mA

No-load operation

Outputs, short circuit proof

2 x PNP, 0.3 A

Max. capacitive load 0.5 µF

Output voltage

> U

sp

– 1

Load 0.1 A

Response time t

R-BWS

Selection table

Page 18

Connector

M12 qd

Connection cable

Max length 5 m

Cross section max. 1.5 mm

2

Outside diameter of cable

3 ... 6.5 mm

for M12

Mode of operation

Guard only with automatic restart

Safety category

Type 4

Self testing

Standards

IEC 61496 part1+2

Electromagnetic compatibility (EMC)

IEC 61 496 part 1

Enclosure rating

IP65

Temperature range

0 ... +55°C

Operation with ILAS

-20 ... +60°C

Storage / transport

Relative air humidity

15 ... 95 %

Non condensing

Enclosure

Aluminum profile 30 x 40 mm

Optical window

Polycarbonate, bonded

Enclosure treatment

Polyester powder coated

Silicon free manufactured

ILAS

Laser class 2

EN 60 825

Dimensions

Dimensions and selection tables

Page 17 + 18

Weight

Selection tables

Page 18

PAC operating range

0 - 30m

2 and 3 segments