8. Selection of a safety light curtain

8.1. Check list

In consideration of following points the selection of a

proper GuardShield Safe 4 safety light curtain will be
simplified:

1. Regulations

Look up carefully the actual regulations and

codes applicable to the particular application in
your country. Local authorities and professional
organisations

as

well

as

ROCKWELL

AUTOMATION representatives will provide
necessary assistance.

USA: Occupation

Safety

and

Health

Administration OSHA, others like ANSI, RIA and
further professional organisations

GB: Health and Safety Executive HSE, safety

con-sultants and professional organisations.

8.2. Selection table

Table 3: 14 mm resolution with ILAS

Catalog No.

Protective Total length B Response time t

R

Max. range Resolution Weight per pair

height A

(mm)

(ms)

(m)

(mm)

(kg)

(mm)

445L-P4L0120YD

120

290

10.5

6

14

1.0

445L-P4L0240YD

240

410

15.8

6

14

1.4

445L-P4L0360YD

360

530

21.1

6

14

1.8

445L-P4L0480YD

480

650

26.3

6

14

2.2

445L-P4L0600YD

600

771

31.6

6

14

2.6

445L-P4L0720YD

720

891

36.9

6

14

3.0

445L-P4L0840YD

840

1’011

42.2

6

14

3.5

445L-P4L0960YD

960

1’131

47.5

6

14

4.0

445L-P4L1080YD

1’080

1’252

52.8

6

14

4.0

445L-P4L1200YD

1’200

1’372

58.1

6

14

4.5

445L-P4L1320YD

1320

1492

63.4

6

14

5.0

445L-P4L1440YD

1440

1612

68.7

6

14

5.5

445L-P4L1560YD

1560

1733

74.0

6

14

6.0

445L-P4L1680YD

1680

1853

79.3

6

14

6.5

445L-P4L1800YD

1800

1973

84.6

6

14

7.0

445L-P4L1920YD

1920

2145

89.9

6

14

7.5

2. Protective field

Determination of

required operating range,

protective height (available in increments

of 120 mm),

resolution (object detection capability: 14

mm or 30 mm)

Operating range and protective height must

be chosen so that the danger points are only
accessible through the protective field.

3. Response time

The response time t

R-BWS

of a GuardShield Safe

4 can be found on the product label and in the
selection table (next section).

4. Corner mirrors

Using corner mirrors allows safeguarding of two

or three protective fields with one light curtain.

Each corner mirror helps reduce the operating

range by approximately 15 % per mirror.