( 39 / 74 )

(3) Connecting 100-pin 0.65-mm-pitch Foot Pattern (Part 2)

Figure 3.14 shows how to connect the emulation pod probe to the 100-pin 0.65-mm-pitch foot pattern
on the target system with the DIRECT100S (not included), and here following is its procedure. For
details on the 100LCC-DMS and DIRECT100S, refer to each user's manual.

(1) Attach the DIRECT100S to the target system.
(2) Attach the 100LCC-DMS to the DIRECT100S.
(3) Attach the M30800T-PTC to the FLX160-PRB.
(4) Attach the M30800T-PTC to the 100LCC-DMS.

Figure 3.14 Connecting emulation pod probe and 100-pin 0.65-mm-pitch foot pattern (part 2)

CAUTION

Notes on Connecting the Target System:

• Take care not to attach the converter board in a wrong direction. It may cause a fatal

damage to the emulation pod.

• The small connectors of 100LCC-DMS and DIRECT100S are guaranteed for only

20 insertion/removal iterations.

• The small connectors of M30800T-PTC are guaranteed for only 50 insertion/

removal iterations.