RuggedBackbone™ RX5000

Installation Guide

Chapter 2

RuggedBackbone™ Modules

3

RuggedBackbone™ Modules

The RX5000 chassis features ten slots, each designed to accommodate a particular module.

Figure 1, “Chassis

Slot Assignment”

shows the front panel view of the RX5000. The slot name at each position indicates the type of

module that can be installed at that position in the chassis.

Figure 1: Chassis Slot Assignment

Table 1: RX5000 Chassis Slots

Slot Type

Description

CM

The Control Module is the central processing unit for the RX5000

system. See

Section 2.2, “Control Module”

.

SM

The Switch Module contains the chassis-wide Ethernet switch fabric

that interconnects Ethernet ports on all installed line modules. See

Section 2.3, “Switch Module”

.

L1 through L6

One to six Line Modules can be installed in the RX5000. See

Section 2.4, “Line Modules”

.

PM1, PM2

Dual, redundant hot-swappable power supply modules can be

installed in the RX5000. See

Section 2.5, “Power Module”

.

All supported modules are built to the RuggedRated™ specifications of the RuggedBackbone™ RX5000.