PLUMBING

Intake Lines

Pressurized Freshwater Models

Install a shut off valve in intake line before water solenoid
valve.
1. Connect hose from shut off valve to inlet port of

water solenoid valve at the toilet.

NOTE: To avoid malfunction of water solenoid due to

debris in water, installation of Freshwater Strainer
(190601) is recommended.

Remote Sea Water Models

Intake pump fittings are interchangeable to allow more
flexibility during installation. Inlet ports are located on
either side of intake pump. Outlet port (to toilet bowl) is
at top of intake pump.

NOTE: To avoid poor pump performance installation

of strainer (163000) is recommended

1. Slide fitting clips to open position.

2. Select inlet port to be used.

3. Install appropriate fittings into inlet and outlet ports.

NOTE: The 90° fitting can be rotated 360°.

4. Install the plug fitting into unused inlet port.

IMPORTANT: Be sure not to install plug fitting
into outlet port! Damage to pump will occur!

5. Slide fitting clips back to closed position.

6. Connect hose from seacock to inlet port of optional

In-Line Strainer if installed. Use hose clamp
provided.

7. Connect hose from outlet port of In-Line Strainer to

inlet port of intake pump. Use hose clamp provided.

IMPORTANT: Double clamp all below waterline
hose connections!
8. Connect hose from outlet port of intake pump to

bowl elbow located on back of toilet bowl.

From

Seacock

To Intake

Pump

Arrow

Open

Closed

Plug

From

Strainer

Inlet Ports

Outlet Port

To Bowl

Inlet

port

Discharge

port