D. WIRING

WARNING: Hazard of Shock and Fire

Always use proper wire, wire connectors and
fuse/circuit breaker. See Specification
Chart.

Secure wire properly.

Do not connect appliances to toilet circuit.

Make sure power is off before proceeding.

Use proper wire terminals for all wire
connections.

1. Determine proper wire size by measuring distance

from:

Power Source to push button to toilet motor
and back to power source.

Remote pump units - also include distance
from power source for remote pump to
remote pump and back. Same wire gauge
must be used for both lower base and remote
pump.

2. Select proper wire and fuse/circuit breaker size

from Specifications on Installation page.

3. Install fuse/circuit breaker in positive line at source.

4. Wire control to the toilet and battery using one of

the following wiring diagrams.

WIRING

To start Electroscan from toilet control, run a wire
from “to EST “ to terminal marked “EXT TRIG”
inside Electroscan control module (black box).
To start Elegance equipped with Smart Switch from
Electroscan, connect “Head1” to “FROM EST “.
For Lectra/San MC, call Raritan Customer Service

ELECTROSCAN OPERATION

Smart Flush Control

Fig. 13