Specifications – Raymarine S1000 User Manual

Page 33

Advertising
background image

S1000 Autopilot Installation Guide

31

Specifications

System

Approved by: FCC (USA), CE (Europe), IC (Canada)

Autopilot pump

Current consumption: 4 A at 100 psi (69 kP), 7 A at 500 psi (3449 kP)
Dimensions: 6.5 in (165 mm) x 2.5 in (65 mm) x 3.2 in (82 mm)
Weight: 3 lbs (1.4 kg)

Course computer

Voltage: 10 V dc to 16 V dc
Current consumption: 4 A nominal, with autopilot pump running
Dimensions: 6.5 in (165 mm) x 6.7 in (170 mm) x 1.73 in (44 mm)
Data In/Out: SeaTalk, NMEA 0183

S100 Remote

Voltage: 3 V, supplied by two internal, ‘AAA’ batteries.
Dimensions: S100 Remote only: 101 mm x 60.5 mm x 35 mm

Remote in cradle:103 mm x 66 mm x 44 mm

Waterproofing: IPX 6 and IPX 7

Hydraulic fittings

Tapered thread: ¼ NPT (National Pipe Thread)
Hose connection thread:

9

/

16

UNEF (Unified Extra Fine)

Hydraulic fluid

Recommended Type: SeaStar/BayStar Marine Steering Fluid
Other suitable Types: Texaco HO15

Shell Aero 4
Esso Univis N15
Chevron Aviation Fluid A
Mobil Aero HFA
Fluids meeting MIL H5606 specifications

87040_5.book Page 31 Monday, April 30, 2007 5:58 PM