Specifications – RTS TBX - TriBus ADAM User Manual

Page 9

Advertising
background image

5

Specifications

NOTE:

The TBX–Tribus supports up to eight (8) frames in non-redundant mode. Slot 10 should be used if a third TBX–

Tribus card is needed.

Board Performance

Throughput Per Link:

360Mb/sec

SFP Fiber Transceivers:

Voltage:

3.3 V Rails

Standard Rate:

SONET OC12 or Gigabit Ethernet

Recommended Parts:

Multi-Mode:

Finisar - FTLF8519P2BNL (Oxide VCSEL, Maximum reach of 550m)

Single Mode:

Finisar - FTLF1422P1BTL (1310nm, Maximum reach 40km)

Fiber Cable Connector Type:

Multiple Mode Fiber LC–LC Duplex Connector – max length 500m (546.8 yd.)

Single Mode Fiber LC–LC Duplex Connector – max length 40km (24.9 miles)

Configuration Requirements

An MCII-e Master Controller card must be installed in the same frame as the TBX-Tribus. For more information, see
the MCII-e User Manual which can be found at www.rtsintercoms.com.

TABLE 1.

Systems Supported by the TBX-Tribus Card

Links Used

# TBX Cards

per Frame

System

Frames Supported

Channels

1

1

AIO-8

2

256

1

1

AIO-16

2

512

3

1

AIO-8

3

384

3

1

AIO-16

3

768

6

1

AIO-8

4

512

6

1

AIO-16

4

880

10

2

AIO-8

5

640

10

2

AIO-16

5

880

15

2

AIO-8

6

768

15

2

AIO-16

6

880

21

2

AIO-8

7

880

21

2

AIO-16

7

880

28

3

AIO-8

8

880

28

3

AIO-16

8

880

Advertising