Installation, Gravity air feed kit option – Regency Wraps Z2510L User Manual

Page 14

Advertising
background image

Regency Z2510 WarmHearth

14

INSTALLATION

GRAVITY AIR FEED KIT OPTION

The Gravity Air Feed Kit is designed to extend the heat output vent above the WarmHearth or to the
front or the side. The upper louver opening is blocked off and flex duct is
connected to the vent holes in the top of the unit and run to vent grills installed
above the unit or to the side. Both 8" diameter insulated Flex pipes must be
used along with the air vent to bring additional air into the chase.

OPTION 2

External Blower with Thermo-Disc

The thermodisc allows the fireplace to warm up
properly before the blower will switch on. The
blower is also switched off if the fireplace
temperature falls below suitable heating levels.

OPTION 3

Internal and External Blowers

with a Thermodisc

When both blowers are used the thermodisc
should be connected to the external blower.

Note: There are two holes provided for attach-

Parts List

Qty.
1

Block-off plate 6-1/2" x 26"

4

Connector collars

4

Adjustable clamps

2

Upper air vent frame

2

5' lengths of flexible vent pipe (8" dia.)

2

Large upper vent covers

1

Small lower vent cover

1

Lower air vent frame

2

Insulation sleeves for flexible vent pipe

1) Remove the screws from both of the vent hole

covers (Vent cover A) on top of the unit.

2) Take the connector collar and rotate it in the

hole to cut through 4" of insulation. Remove the
insulation from pipe.

3) Remove the screws on the lower cover (Vent

cover B) and slide it back under the insulation.

4) Slide the connector collar into the flex duct and

secure with an adjustable clamp.

FAN PART NUMBERS

The parts listed below are available from Re-
gency. Please see your Regency Dealer for
prices.

000-912

Internal Blower Assembly:
Includes 150 CFM, 2 speed blow-
er, Blower Switch Kit and Ther-
mo-Disc Kit.

000-928

Blower Switch Kit:
Includes switch box, two way
switch and a three way switch.

ing the thermodisc to the fireplace. The
holes are on the right hand side just
below the ashlip.

(Fastens to louvers)

000-918

One-way Damper:
Eight inch diameter butterfly valve
necessary for external blower
installation.

The remainder of the components discussed
here are optional and are available from your
Regency dealer or local heating supply outlet.
Below is the listed specifications required for
these parts:

External Blower: 8 inch diameter inlet a mini-

mum capacity of 433 CFM at
a static pressure of 0.75 in.
w.c. and is listed in the coun-
try where the blower is to be
used.

Wall Switch:

1 speed blower requires
2-way switch
2 speed blower requires
3-way switch etc.

Wall Thermostat: For both wall switch and

thermostat see your Regen-
cy dealer or heating supplier
for compatible parts.