Ventilated Chase Pan

In Canada:

Any factory built chimney listed and certified to
ULC-S629. Also any of the following chimney
covered by ULC-S610 or ULC S604.

1)

GSW Heating Products Model JFC

2)

Oliver McLeod Ltd. Model PRO-JET 3103

3)

Security Chimney Ltd. Model ASHT

4)

Selkirk Metalbestos Model SS

5)

ICC Excel 103 HT

6)

ICC Excel 2100

In U.S.A.

Any of the following chimney systems covered
by UL-103HT may be used.

1) American Metal Product AMERI-TEC

Model HS

2) GSW Heating Products Model FC
3) Oliver McLeod Ltd. Model PRO-JET 3103
4) Security Chimney Ltd. Model ASHT
5) Security Chimney Ltd. Model S2100
6) Security Chimney Ltd. Model Sentinel
7) Selkirk Metalbestos Model SS II
8) Simpson Dura-Vent Model Dura-Plus
9) ICC Excel 103 HT
10) ICC Excel 2100

Note: Anchor Plate/Fireplace Adaptor
must be purchased with Chimney sys-
t e m .

The use of only one of these systems is
permitted when installing the WarmHearth. Do
not alter or mix parts from other systems as this
may cause a potential hazard and void Regen-
cy’s limited warranty.

INSTALLATION

support as well as the floor beneath the
hearth extension.

Note: The “Z” type safety strip is not

supplied by Regency and must be
fabricated locally.

2) Refer to fireplace drawing and specifica-

tions on page 6 and page 7 for framing
dimensions and details. framing header
may be positioned directly on top of the
front fireplace stand-offs.

IMPORTANT: Under no circumstanc-
es can the fireplace top or side
spacers be removed or modified.
Do not notch the header to be in-
stalled closer than the fireplace out-
side facing spacers.

3) Fireplace must be anchored to the framing

to prevent movement or rocking; use wall
grips or seismic brackets which have been
supplied. These angle brackets are installed
by attaching them to the side of the unit and
to the back side of the 2 x 4 or further back
on 2 x 6 framing.

CHIMNEY SYSTEM

CONSIDERATIONS

Regency’s WarmHearth Fireplace is to be in-
stalled with one of the following Chimney Sys-
tems only. Chimney systems going from 7 in. to
8 in. diameter (with adaptor #000-924) may be
used.

Chimney Height

The total height of your WarmHearth fireplace
system from the surface the fireplace rests on
to the chimney top must not exceed 36 ft. and
must also meet minimum system height chart.
Please refer to the Flue Manufacturer's Instruc-
tions for specific details. Refer to Page 12 for
Minimum Flue System Heights.

Chase Enclosure

A chase is a vertical box-like structure con-
structed to surround the fireplace and chimney.
A ventilated chase cap is highly recommended.
Refer to flue manufacturer's instructions for
reduced flue heights above chase termina-
tions. ICC and Dura-Vent allow for reduced
height with ventilated chase flashing. As with
all chimney installations, avoid overhead ob-
structions such as trees, power lines, etc.

A chase should be constructed just like any
outside wall. In a cold climate, we recommend
the base of the chase be insulated between the
solid continuous floor beneath the fireplace
and the chase bottom. If used, the value and
amount of chase insulation in a cold climate
installation is optional and not required for
safety. Insulation is recommended to avoid
heat loss.

Note: Insulation does not come in contact with
Chimney. Maintain a 2 in. clearance.