Specifications, Rlc-1080 power conditioner – ROTEL RLC-1080 User Manual

Page 14

Advertising
background image

14

RLC-1080 Power Conditioner

Specifications

INPUT

Voltage Range for Operation on Utility

90V – 144V

Nominal Voltage

120 VAC

Allowable Frequency for Operation on Utility 47 – 63 Hz
Rated Input Current

12 Amps

Circuit Breaker Rating

15 Amps

OUTPUT

Number of Outlets

12 (all outlets are surge protected, conditioned,

regulated and battery backed up)

Outlet Type

NEMA 5-15R

Rated VA Capacity

1440 VA

Rated Watt Capacity (continuous)

900 Watts

Rated Output Current

12 Amps

BATTERY BACKUP

Transfer Time to Battery During Blackout

7ms typical, 10ms maximum

Battery Type/Quantity

Four 12V/9A hr Sealed Lead-Acid, Maintenance Free

Typical Recharge Time to 90% Capacity

<8 hrs

Battery Service

User replaceable, Hot swappable

Battery Life

2-5 Years (Depending on use, environment,

and temperature)

Battery Runtime

20 minutes (half load) or 7.5 minutes (full load)

(Actual runtimes are determined by load, battery

charge level, battery health and quantity of batteries

installed)

SURGE PROTECTION

Let-Through Voltage Rating

<40V

Data Line Protection Jacks

RJ45

COAX

3 pair + splitter

Ethernet

1 pair, 10/100bT

Telephone/DSL

2 line, 4 wire with splitter

DC Trigger

Two 3.5mm mini-jack plugs (5-30V)

PHYSICAL

Unit Dimensions

17 x 5.25 x 18.55 in.

43.2 x 13 x 47.1 cm

Unit Weight

57 lbs / 26 kgs

CONFORMANCE

Safety Agency Approvals

UL1778 (tested to relevant UL1449), CSA,

FCC Part 68 Class B

Warranty

2 years

All specifications are accurate at the time of printing.
Rotel reserves the right to make improvements without notice.