Heat trap, Relief valve insulation installation – Rheem Warrior Series AP10414-9 User Manual

Page 11

Advertising
background image

Heat Trap

For increased energy efficiency, some
water heaters have been supplied with
factory installed internal or external heat
traps in the hot outlet and cold water inlet
openings.

NOTICE: Do not apply heat to the HOT or
COLD water connections. If sweat
connections are used, sweat tubing to
adapter before fitting adapter to the water
connections on heater. Any heat applied to
the water supply fittings will permanently
damage the dip tube and/or heat traps.

11

For increased energy efficiency, some
water heaters have been supplied with
a 2-3/8” section of pipe insulation.

Please install the insulation, according to
the illustrations above, that best meets
your requirements.

Slip the insulation cover over the T&P
Valve through the center hole and align
the hole in the side with the opening of
the T&P Valve.

R

E

L

I

E

F

V

A

L

V

E

COLD

HOT

Typical top connection arrangement

Typical side connection arrangement

Relief Valve Insulation Installation

CAUTION: Ensure the

T&P Valve opening is not
obstructed by the insulation.

Advertising