Roubleshooting – Rockford Fosgate RFX9000 User Manual

Page 25

Advertising
background image

25

T

ROUBLESHOOTING

S

YMPTOM

D

IAGNOSIS

R

EMEDY

Source unit is not grounded prop-
erly

Noise is radiating into RCA signal
cable

Bad component in the signal
chain

Noise is radiating into the speak-
er cables

Multiple grounds in the audio
system

Check connections and repair wiring as neces-
sary

Check connections, run the RCA cables on a
different route away from sources of high cur-
rent

Check connections. Bypass all components
between the Source unit and the amplifier.
Connect one component at a time to deter-
mine the culprit. Repair or replace components
as necessary

Disconnect speakers and connect a test speak-
er to the output terminals or the source unit. If
noise is gone, reroute the speaker cables away
from sources of high current

Check ground connections and connect ampli-
fiers, signal processors, and other components
to a central location or try a different grounding
point on the chassis

Engine Noise

Batteries are weak

Excessive dirt or dust on IR
Remote transmitter lens

Excessive dirt or dust on source
unit receiver lens

IR remote is outside of optimum
transmitting range

High sunlight conditions

Check battery condition and replace as neces-
sary with (1) CR2025 (+3 volt) battery

Clean transmitter lens with Plexiglas solution
and a non-abrasive cloth as necessary

Clean receiver lens (compact disc logo) with
Plexiglas solution and a non-abrasive cloth as
necessary

Operate IR remote within about 15 ft and ±45˚
from horizontal of the Source unit’s faceplate

Operate IR remote closer to Source Unit

IR Remote has
poor range

Batteries are dead

Battery is installed incorrectly

Check battery condition and replace as neces-
sary with (1) CR2025 (+3 volt) battery

Check battery installation and repair as neces-
sary (polarity is indicated on pc board)

IR Remote
does not work

(LED does not
illuminate)

Advertising