Chapter 5. Troubleshooting

When this product does not work properly, check the following.

5.1 When the Emulator Debugger Does Not Operate

(1) Errors Occur When Operating the Emulator Debugger

(When the target system is connected)

Table 5.1 Checkpoints of errors when starting up the emulator debugger M3T-PD79 (target is connected)

Error

Communication ERROR
Data is not sent to the target

Target system is not constructed properly

The version of M3T-PD79 and the firmware
on the target system are not same

Target MCU is reset state

Target MCU cannot be reset
Flash ROM erase error occurred

Target clock is stopped

Target MCU is not receiving power

Not connected to target
Cannot connect to target

Target MCU is uncontrollable
Reset target system

Checkpoint

Check all emulator debugger settings, interface cable
connections and switches on the rear of the PC4701
match.

- See the user's manuals of the PC4701 and emulator
debugger.

(1) Download the proper firmware.

- See the user's manuals of the emulator debugger.

(2) Recheck the connection between the PC4701, the

emulation pod and this product.

- See "3.3 Connecting the Emulation Pod Main Unit"
(page 22).
- See user's manual of the M37900T2-RPD-E.

Download the proper firmware.

- See the user's manual of the emulator debugger.

(1) Check the reset pin of the target system is pulled up.
(2) Check the reset pin of the target system has changed

from "L" to "H" level.

(1) If the reset circuit of the target system has a watchdog

timer, disable the timer.

(2) Check power is properly supplied to the target system

and that the target system is properly grounded.

(3) Check your emulator debugger M3T-PD79 is Ver.2.10

or greater.

(4) The flash ROM of the MCU may be worn-out. Contact

your local distributor.

Check the oscillation circuit of the target system is
oscillating properly.

Check power is properly supplied to the target system
and that the target system is properly grounded.

(1) Recheck the connection of the emulation pod and this

product.

- See "3.3 Connecting the Emulation Pod Main Unit"
(page 22).

(2) Recheck the connection of the SSOP42B-450 and

the socket.

- See "3.4 Connecting the Target System" (page 24).

Check the program is not accessing to the unused area.