Discharge Lines

1. Connect quality sanitation hose 1"

(25mm) or 1 1/2" (38mm) I.D. to
discharge fitting on toilet.

2. Run hose to appropriate device (i.e.:

treatment system, holding tank, etc.).

PLUMBING

WARNING: Hazard of Flooding

Toilets mounted at or below the waterline
must have a vented loop installed in the
discharge line. The top of the vented loop
must be a minimum of 4" (10cm) above
the waterline at the boats greatest angle
of heel (see vented loop manufacturer’s
instructions).

Sea Water Models must also have a vented
loop installed between the intake pump
and the toilet bowl.

Double clamp all below waterline
connections.

IMPORTANT

Fittings and 90° bends should be kept
to a minimum.

In-Line Strainer must be installed on
Sea Water Models per Installation
Instructions. Failure to do so may void
Warranty.

Discharging untreated sewage is
forbidden in all U. S. waters within the
three-mile limit.

Thru-hull fittings and seacocks must
be installed where they are easily
accessible.

Use only quality reinforced hoses.

Secure all hoses properly.

Pressurized Freshwater Model

Installed Above Waterline

SeaEra

Toilet

Vacuum

Breaker

Water

Solenoid

Valve

Discharge

Holding Tank

Pressurized Freshwater

Source

Waterline

Shut off

Valve

Sea Water Model with Integral Pump

Installed Below Waterline

SeaEra

Toilet

Waterline

Intake Vented

Loop

Intake

Seacock

Remote

Intake

Pump

In-Line

Strainer

Discharge

Seacock

Discharge

Vented

Loop

Intake

Seacock

Holding Tank

SeaEra Toilet

Y Valve

In-Line

Strainer

Lectra/San

Waterline

Waterline

Waterline

Remote Intake Pump Model

Mounted Above Waterline

Discharge

Seacock

Waterline

Discharge

Vented

Loop

Lectra/San

1 1/2" (38mm)

Discharge Fitting

1" (25mm)

Discharge Fitting

Hose