From

Seacock

To Intake

Pump

INST

ALLA

TION

Intake Lines

Pressurized Freshwater Models

Install a shut off valve in intake line before water
solenoid valve.
1. Connect hose from shut off valve to inlet port

of water solenoid valve.

NOTE: To avoid malfunction of water solenoid due

to debris in water, installation of Freshwater
Strainer (190601) is recommended.

2. Connect hose from outlet port of water solenoid

valve to inlet port of vacuum breaker.

3. Connect hose from outlet port of vacuum breaker

to bowl elbow.

NOTE: Vacuum breaker must be last mechanical

component before bowl elbow.

Sea Water Models

Intake pump fittings are interchangeable to allow
more flexibility during installation. Inlet ports are
located on either side of intake pump. Outlet port
(to toilet bowl) is at top of intake pump.

1. Slide fitting clips to open position.

2. Select inlet port to be used.

3. Install appropriate fittings into inlet and outlet

ports.

NOTE: The 90° fitting can be rotated 360°.

4. Install the plug fitting into unused inlet port.

IMPORTANT: Be sure not to install plug fitting
into outlet port! Damage will occur!

5. Slide fitting clips back to closed position.

6. Connect hose from seacock to inlet port of

In-Line Strainer. Use hose clamp provided.

7. Connect hose from outlet port of In-Line

Strainer to inlet port of intake pump. Use hose
clamp provided.

IMPORTANT: Double clamp all below
waterline hose connections!
8. Remote Pump Models Only: Connect hose

from outlet port of intake pump to bowl elbow
located on back of toilet bowl. (Integral pump
model is already connected).

From Pressurized

Freshwater Source

(Shut Off Valve)

To Inlet Port

of Vacuum

Breaker

Inlet Ports

Outlet Port

Arrow

OUT

IN

Open

Closed

Plug

From Strainer

To Bowl

Outlet Port

Inlet Port