Chassis ground connection, Ac power supply wiring example, 3 chassis ground connection – RuggedCom RUGGEDBACKBONE RX1501 User Manual

Page 25: 4 ac power supply wiring example, Section 3.2.4, “ac power supply wiring example

Advertising
background image

RuggedBackbone™ RX1501

Installation Guide

Chapter 3

Installation

Chassis Ground Connection

19

Section 3.2.3

Chassis Ground Connection

The RX1501 chassis ground connection, shown in

Figure 42, “Chassis Ground Connection”

, uses a #10-32

screw. It is recommended to terminate the ground connection in a #10 ring lug. Torque on the chassis ground

connection should not exceed 30 in-lbs (3.4 Nm).

Figure 42: Chassis Ground Connection

Section 3.2.4

AC Power Supply Wiring Example

Figure 43: Wiring for Single AC Power Supply (HIP module shown)

NOTE

• For 125/230VAC rated equipment, a appropriately rated AC circuit breaker must be installed.
• It is recommended to provide a separate circuit breaker for each power supply module.
• Equipment must be installed according to applicable local wiring codes.