Water temperature too high, Temperature pressure relief valve running, On p – Rheem Electric Domestic Water Heater User Manual

Page 13: Er to, Temperature, Pressure relief valve running, Save a service call

Advertising
background image

SAVE A SERVICE CALL

Water heater size
Do you have the correct size water heater for your requirements? The sizing
guide in the Rheem sales literature and on the Rheem website

(www.rheem.com.au)

suggests average sizes that may be needed.


WATER TEMPERATURE TOO HIGH
A RheemPlus water heater is fitted with a temperature limiting valve set to
deliver water not exceeding 50

°C. If the water is being delivered at a

temperature exceeding 50

°C, phone your nearest Rheem Service Department

or Accredited Service Agent to arrange for an inspection. Care must be taken
by all householders when using hot water until the valve is serviced or
replaced.

TEMPERATURE PRESSURE RELIEF VALVE RUNNING

Normal Operation
It is normal and desirable that this valve
allows a small quantity of water to escape
during the heating cycle. However, if it
discharges more than a bucket full of water
in 24 hours, there may be another problem.

13

Continuous dribble
Try gently raising the easing lever on the
relief valve for a few seconds (refer to

“Temperature Pressure Relief Valve”

on

page 10). This may dislodge a small particle
of foreign matter and clear the fault.
Release the lever gently.

Steady flows for long period (often at
night)
This may indicate the mains water pressure
sometimes rises above the designed
pressure of the water heater. Ask your
installing plumber to fit a pressure limiting
valve.

Warning: Never replace the relief valve with one of a higher pressure

rating.

Heavy flows of hot water until water heater is cold - then stops until
water reheats
The water heater must be switched off at the switchboard. Phone your
nearest Rheem Service Department or Accredited Service Agent to arrange
for an inspection.

Advertising