Installation, Minimum clearance to combustible materials – Regency ALTERRA CS1200 User Manual

Page 7

Advertising
background image

Regency CS1200 Freestanding Wood Stove

7

INSTALLATION

MINIMUM CLEARANCE TO COMBUSTIBLE MATERIALS

MEASUREMENTS "FROM UNIT" ARE FROM THE SIDE SHIELDS OF THE STOVE TO A SIDE WALL OR TO A CORNER, AND

FROM THE REAR HEAT SHIELD TO A BACK WALL

NOTE: Be aware that local Codes and Regulations may override some clearances listed in this manual.

Check with your local inspector.

Residential Installation “C” Vent (Single Wall)

Unit

From Unit

From Corner

From Flue Center-line

CS1200

A

B

C

D

E

F

13"

11"

8"

26-3/8"

18-1/2"

20-3/4"

Residential Close Clearance (To be installed with required pipe components)
When the stove is installed as a close clearance residential unit, a listed double wall connector is required from
the stove collar to the ceiling level.

From Unit

From Corner

From Flue Center-line

CS1200

A

B

C

D

E

F

11"

7"

7"

24-1/2"

14.5"

19-3/4"

Mobile Home Close Clearance (To be installed with required pipe components)
"C" Vent single wall pipe is not approved for Mobile Home installations. (Refer to Mobile Home Instructions.)

From Unit

From Corner

From Flue Center-line

CS1200

A

B

C

D

E

F

11"

7"

7"

24-1/2"

14.5"

19-3/4"

A

F

F

C

C

B

E

D