Notice, Venting instructions (rv53i) – Rinnai RV53I User Manual

Page 25

Advertising
background image

RV53i & RV53e Operation and Installation Manual

25

Vent Products

Manufacturer Product

Parts

Rinnai/Ubbink

Rolux Vent System

Heat-Fab

Saf-T Vent SC system

Metal-Fab

Corr/Guard Vent/Air

Intake System

Refer to the manufacturer’s technical literature for
specific part numbers and instructions.

Listed and Tested Vent Products for RV53i ....................... REU-VB2020FFU-US

Example: If you have one elbow then your maximum vent length is 35 feet (10.7 m). If your actual length is

greater than 15 ft (4.6 m) then move switch no. 1 (SW1) to OFF.

Maximum Vent Length

1. Determine the number of 90 degree elbows in the vent system. (Two 45 degree elbows count as one 90

degree elbow.)

2. Refer to the table to find the maximum vent length based on the number of elbows.

3. Follow the applicable note.

Vent Manufacturer Contact Information for Installation Instructions and Parts Lists:

Heat-Fab

Telephone: 800-772-0739
Fax: 413-863-4803
E-mail:

[email protected]

Web Site: www.heatfab.com

Rinnai/Ubbink

Telephone: 800-621-9419
Fax: 678-829-1666
Web Site: www.rinnai.us

Metal-Fab Inc.

Telephone: 800-835-2830
316-943-2351
Fax:

316-943-2717

E-mail:

[email protected]

Web Site: www.metal-fabinc.com

If you have a longer vent length, switch no. 1 is required to be in the OFF position. This ensures the water
heater will run properly. Blocked flue error codes and shutdowns may result if switch no. 1 is not in the correct
position.

NOTICE

Number of 90° Elbows

0

1

2

3

4

5

6

41 ft 1

(12.5 m)

35 ft 2

(10.7 m)

29 ft 3

(8.8 m)

23 ft 4

(7.0 m)

17 ft 4

(5.2 m)

11 ft 4

(3.4 m)

5 ft 4

(1.5 m)

Notes 1234

1

If the length is greater than 21 ft (6.4 m) then move
switch no. 1 (SW1) to OFF.

2

If the length is greater than 15 ft (4.6 m) then move
switch no. 1 (SW1) to OFF.

3

If the length is greater than 9 ft (2.7 m) then move
switch no. 1 (SW1) to OFF.

4

Move switch no. 1 (SW1) to OFF.

Switch No.

F

O

F

8

5

7

6

4

3

ON

1

2

Venting

Instructions

(RV53i)

Advertising