Temperature controller installation – Rinnai RV53I User Manual

Page 31

Advertising
background image

RV53i & RV53e Operation and Installation Manual

31

Temperature Controller Installation

• The controller should be out of reach of small

children.

• Avoid locations where the controller may become

hot (near the oven or radiant heater).

• Avoid locations in direct sunlight. The digital

display may be difficult to read in direct sunlight.

• Avoid locations where the temperature controller

could be splashed with liquids.

• Do not install in locations where it can be adjusted

by the public.

Configurations

A maximum of 4 temperature controllers, including
wired and wireless, can be installed for a water heater
or bank of water heaters. Controllers can only be
wired in parallel. Controllers cannot be wired in
series.

The 4 temperature controllers can consist of multiple
MC-91’s or MC-502RC’s but only 1 BC-100V and only
1 MC-100V.

Any one of the 5 types of controllers can be installed
by itself and still operate the water heater. All
functions will be available with the exception that the
clock function on the BC-100V will only be available if
an MC-100V is also connected.

If 4 MC-91’s are installed, simultaneously press the
Priority and On/Off buttons on the fourth controller
until a beep sounds.

The table to the right shows some of the possible
combinations of controllers.

Cable Lengths and Size

The cable for the temperature controller should be a
non-polarized two-core cable with a minimum gauge
of 22 AWG. The maximum cable length from each
controller to the water heater depends on the total
number of wired controllers connected to the water
heater.

MC-91 + MC-91 + MCC-91 MC-502RC

MC-91 + MCC-91 + MC-502RC MC-502RC

MCC-91 + MC-502RC + BC-100V

MC-100V

MC-91 + MC-502RC + BC-100V

MC-100V

MC-91 + MC-91 + MC-502RC BC-100V

MC-91 + MC-502RC + MC-502RC

MC-100V

+

+

+

+

+

+

Number of Wired

Controllers

Maximum Cable Length for each

Controller to Water Heater

1

328 ft (100 m)

2

164 ft (50 m)

3 or 4

65 ft (20 m)

Location

Controllers

Wire controllers in parallel

Advertising
This manual is related to the following products: