26 figure 19: u-tube heater layout overview legend – Roberts Gorden Linear Heater User Manual

Page 12

Advertising
background image

BH-S

ERIES

I

NSTALLATION

, O

PERATION

AND

S

ERVICE

M

ANUAL

26

FIGURE 19: U-Tube Heater Layout Overview

LEGEND

a = 14" (36 cm)

Reflector Width (Not Shown)

b = 2" (5 cm)

End Cap to Burner

c = 2" (5 cm)

End Cap to Hanger

d = 7' 6" (2.3 m)

Distance First Hanger

e = 10' (3.0 m)

Distance Between Hangers

f = 5' (1.5 m)

Distance Between Last Full Tube

Hanger and Half Tube Hanger

g = 12.5" (32 cm) Burner Length

h = 11" (28 cm) Burner Height

* Requires the last reflector

before the u-tube to be cut in

half for use on both sides.

** Requires the last tube before

the u-tube to be cut in half for

use on both sides.

U-tube

Burner

Reflector

Tube 10' (3.0 m)

Tube/Reflector

Hanger
Coupling

Assembly

Tube 5' (1.5 m)**

c

b

d

e

g

h

40

'

(12.2 m) Tube Length

c

b

d

f

g

h

30

'

(9.1 m) Tube Length**

20

'

(6.1 m) Tube Length*

g

c

b

h

e

c

b

d

e

f

g

h

50

'

(15.2 m) Tube Length* **

Vent Adapter

(Not Shown)

Advertising