Termination clearances sidewall power vent, Vent pipe termination – Reliance Water Heaters 317686-000 User Manual

Page 19

Advertising
background image

19

terMInatIon clearances sIdewall power vent

V

X

VENT TERMINAL

AIR SUPPLY INLET

AREA WHERE TERMINAL IS NOT PERMITTED

v

v

A

G

V

FIXED

CLOSED

FIXED

CLOSED

OPERABLE

OPERABLE

V

C

B

B

B

B

F

B

V

V

A

J

V

H

M

X

X

V

V

K

B

E

D

L

POWER VENT

(using room air for combustion)

EXTERIOR CLEARANCES FOR SIDEWALL VENT TERMINATION

fIGure 15.

Vent terminal clearances for “Power Vent” installations. Power Vent configurations use room air for combustion.

us InstallatIons

us InstallatIons

a

Clearance above grade, veranda, porch,

deck or balcony

12 inches (30 cm)

h

Clearance to each side of center line

extended above meter/regulator assembly

3 feet (91 cm) within a height 15 feet (4.5 m)

above the meter/regulator assembly*

B

Clearance to window or door that may

be opened

4 feet (1.2 m) below or to side of opening; 1

foot (30 cm) above opening

I

Clearance to service regulator vent outlet

3 feet (91 cm)*

c

Clearance to permanently closed window 12 inches (30 cm)*

j

Clearance to a non mechanical air supply

inlet into building or combustion air inlet to

any other appliance

4 feet (1.2 m) below or to side of opening;

1 foot

(30 cm) above opening.

d

Vertical clearance to ventilated soffit

located above the terminal within a

horizontal distance of 2 feet (61 cm) from

the center line of the terminal

12 inches (30 cm)*

K

Clearance to a mechanical air supply inlet

3 feet (91 cm) above if within

10 feet (3 m) horizontally

e

Clearance to unventilated soffit

12 inches (30 cm)*

l

Clearance above paved sidewalk or paved

driveway located on public property

7 feet (2.13 m)

f

Clearance to outside corner

2 feet (60 cm)*

M

Clearance under veranda, porch, deck, or

balcony

12 inches (30 cm) ‡

G

Clearance to inside corner

18 inches (45 cm)*

In accordance with the current ANSI Z223.1/NFPA 54, National Fuel Gas Code.

† A vent shall not terminate directly above a sidewalk or paved driveway that is located between two single family dwellings and serves both dwellings.

‡ Permitted only if veranda, porch, deck, or balcony is fully open on a minimum of two sides beneath the floor.

* Clearance in accordance with local installation codes and the requirements of the gas supplier and the manufacturer’s installation instructions.

vent pIpe terMInatIon

The first step is to determine where the vent pipe will terminate.

See Figures 15, 20 and 21. The vent may terminate through a

sidewall as shown in Figure 20 or through the roof as shown

in Figure 21.

The vent system must terminate so that proper clearances are

maintained as cited in local codes or the current edition of the

National Fuel Gas Code, (ANSI Z223.1, 12.9.1 through 12.9.4).

Instructions on proper installation through a sidewall are provided

in Figure 15.
Plan the vent system layout so that proper clearances are

maintained from plumbing and wiring.
Vent pipes serving power vented appliances are classified by

building codes as “vent connectors”. Required clearances from

combustible materials must be provided in accordance with

information in this manual under LOCATING THE NEW WATER

HEATER and INSTALLING THE WATER HEATER, and with the

National Fuel Gas Code and local codes.