vent attenuatIon asseMBlY

InstallatIon InstructIons

The Vent Attenuation Assembly (VAA) is designed to provide a

reduction in fan noise created in the blower wheel. This installation

of this VAA is optional. Review directions thoroughly prior to installing

the new VAA. Please contact the manufacturer of the water heater as

shown in the instruction manual with any questions or for additional

product support.

vent attenuatIon asseMBlY KIt parts lIst

The kit consists of the following items. If a part is missing, use the

contact information in the instruction manual to acquire missing

component(s).

• vent attenuation assembly

• flexible tubing

• instruction sheet

vent attenuatIon asseMBlY InstallatIon

The VAA is designed for both vertical and horizontal installations.

The vertical installation and horizontal installations will require that

the flexible condensate hose to be attached to the condensate hose

barb located on the bottom of the VAA to release condensate. See

instructions and diagrams that follow for a more detailed description.

Breathing Hazard - Carbon Monoxide Gas

Do NOT block the holes in the hex plug of vent pipe

assembly #1.

Do NOT elevate any portion of the field supplied drain

line beyond the 1/2" adaptor above the adaptor. This

must be true for entire length of the drain line including

the exit into an appropriate drain.

Condensate lines must be free and clear of debris and

must not allow back flow through drain line. Condensate

lines must be able to flow freely to an appropriate drain.

Do not allow condensate lines to become crimped closed.

Analyze entire vent system to make sure that condensate

will not become trapped in a section of vent pipe and

therefore reduce open cross sectional area of vent.

Breathing carbon monoxide can cause brain damage or death.

Always read and understand instruction manual.

Vertical VAA Installations (Recommended)
1. The VAA is designed to accept two inch PVC pipe into

the adapters on both ends. The VAA must be installed with the

condensate hose barb pointing downward. See Figure 22. The

VAA has an embossed flow arrow to reflect proper orientation.

For optimum performance, install VAA as close as possible to

the blower assembly.

2. Use standard PVC cement (not included with kit) and glue the two

inch PVC pipe coming from the blower into the VAA.

3. Perform the same sequence on the PVC pipe coming from the

exhaust side (vent terminal side) of the VAA.

4. Make sure the VAA and vent pipe is supported securely to

a permanent fixture (stud or wall). Use standard support

straps (not supplied with kit) that may be found at a local

hardware store. Failure to properly support the VAA and the

surrounding vent pipe could create a hazardous situation. DO

NOT puncture any surface of the VAA.

5. Locate flexible tubing. Slide one end of tubing over the hose

barb located near end of the VAA. The ridges on the hose

barb should prevent the tubing from sliding off, however,

to ensure there are no leaks and possible dislocation from

hose barb, use a wire tie or hose clamp (not supplied with kit)

and secure.

6. Take the other end of the flexible tubing and slide it through

the hose clamp on the jacket top cover and install it into one

of the four barb fittings in vent pipe assembly #2.

7. Once installed along with the rest of the vent configuration,

make sure to operate the unit through at least one heat up

cycle to ensure there is no leakage around the hose barb or

any joints of the VAA or vent pipe system.

fIGure 22: typical vertical Installation

horizontal vaa Installations
1. The VAA is designed to accept two inch PVC pipe into the

adapters on both ends. The VAA must be installed with the

condensate hose barb pointing downward. See Figure 23. The

VAA has an embossed flow arrow to reflect proper orientation.

For optimum performance, install VAA as close as possible

to the blower assembly.

2. Use standard PVC cement (not included with kit) and glue the

two inch PVC pipe coming from the blower into the VAA.

3. Perform the same sequence on the PVC pipe coming from the

exhaust side (vent terminal side) of the VAA.

4. Make sure the VAA and vent pipe is supported securely to a

permanent fixture (stud or wall). Use standard support straps

(not supplied with kit) that may be found at a local hardware

store. Failure to properly support the VAA and the surrounding

vent pipe could create a hazardous situation. DO NOT puncture

any surface of theVAA.

5. Locate flexible tubing. Slide one end of tube over the hose

barb located near end of the VAA. The ridges on the hose

barb should prevent the tube from sliding off, however, to

ensure there are no leaks and possible dislocation from hose