Nmea 2000, Securing cables and replacing cover, 11 additional connections – Raymarine VolvoPenta IPS Autopilot System DPU User Manual

Page 12: Seatalk2 terminator, Grounding the system, Using the grounding cable, Seatalk, Terminator

Advertising
background image

12

Volvo Penta IPS Autopilot System

NMEA 2000

Using one of the SHORT SeaTalk

2

cables, connect the NMEA 2000 terminal on the

DPU to the FOURTH terminal of the 5 way SeaTalk

2

connector block.

Securing cables and replacing cover

When all of the DPU cables have all been connected, secure each cable to the

loops on the DPU, using the cable ties provided.
When all cables are secure, replace the DPU cover.
Do not use the DPU with the cover removed, as this could degrade the EMC

performance.

1.11 Additional connections

Three more connections now need to be made to the 5 way connector block.

SeaTalk

2

terminator

Plug the SeaTalk

2

terminator into the CENTER terminal on the 5 way SeaTalk

2

connector block.

Grounding the system

In order to meet the system EMC specification, the SeaTalk

2

cable screen must be

connected to the vessel’s RF ground point.

Using the grounding cable
Raymarine provide a made up, RF grounding cable that you are recommended to

use, to ground the system.
The grounding cable is yellow and has a SeaTalk

2

connector at one end. Connect

this to the FIRST terminal of the 5 way SeaTalk

2

connector block. The

Wire Color

DPU Connection

S3G Connection

Red

NMEA 0183 In +

NMEA 1 Out +

Blue

NMEA 0183 In

NMEA 1 Out

Yellow

NMEA 0183 Out +

NMEA 1In +

Green

NMEA 0183 Out

NMEA 1 In

87054_3.book Page 12 Tuesday, July 18, 2006 8:49 AM