Sizing guide & specifications, Sizing guide, Component specification & reference numbers – Redring DC3810 User Manual

Page 15

Advertising
background image

14

SIZING GUIDE & SPECIFICATIONS

SIZING GUIDE

150

201kg

1120 x 560

SINGLE BATH - 3 BED

88mins / 50mins

200

266kg

1470 x 560

TWIN BATH

108mins / 63mins

250

319kg

1770 x 560

TWIN BATH & SHOWER

155mins / 100mins

Heat-up times through 50

o

C. Re-heat is 70% of volume.

CAPACITY

(LITRES)

NOM SIZES

NOM WEIGHT

INDIRECT

(FULL)

DIRECT APPLICATION

HEAT-UP TIME/RE-HEAT TIME

COMPONENT SPECIFICATION

& REFERENCE NUMBERS

DESCRIPTION

SPECIFICATION

PART NUMBER

PRESSURE REDUCING VALVE

NON RETURN VALVE

PRESSURE GAUGE

EXPANSION VALVE

PRESSURE & TEMP RELIEF VALUE

IMMERSION HEATER

IMMERSION HIGH LIMIT THERMOSAT

IMMERSION CONTROL THERMOSTAT

EXPANSION VESSEL

UP TO 170 LITRE MODELS

EXPANSION VESSEL

FOR 200 & 250 LITRE MODELS

TUNDISH

INSTALLATION GUIDE

LABEL

CYLINDER THERMOSTAT

2 PORT VALVE

3.0 BAR CONTROL

22MM X 22MM

0-10 BAR SCALE

6.0 BAR

7.0 BAR/95

O

C

1

3/

4

- 240V ~ 3KW

80

O

C

VARIABLE

3.0 BAR CHARGE, 12 LITRE CAPACITY

3.0 BAR CHARGE, 18 LITRE CAPACITY

1/

2

“ X 22MM

24PP

-

CONTROL & HIGH LIMIT 80

O

C

DANFOSS

97-392056

97-392038

97-392057

97-392058

97-392059

97-392060

97-392061

97-392062

97-392063

97-392064

97-392065

97-392066

97-392067

97-392068

97-392069

INDIRECT APPLICATION

HEAT-UP TIME/RE-HEAT TIME

TWIN BATH

30mins / 21mins

2 BATH & 2 SHOWERS

33mins / 24mins

3 BATH & 2 SHOWERS

36mins / 26mins

NOM WEIGHT

DIRECT

(FULL)

230kg

300kg

360kg

New Stainless imp_alt 2/15/05 12:15 PM Page 15