Open array scanner cables, Inter-unit cable, 12 v systems (4 kw scanners only) – Raymarine Radar Scanner User Manual

Page 24: 24 v and 32 v systems - 4 kw scanners

Advertising
background image

16

Pathfinder Radar Scanners

Open array scanner cables

Inter-unit cable

Heavy duty cables are available in 15 m and 25 m lengths which
should be sufficient to complete the cable run required on most small
vessels. For longer runs, 5 m and 10 m extension cables are available,
both have 4 power cores to minimize voltage drops over the cable run
and incorporate in-line moulded plugs.

The maximum inter-unit cable length is limited by the minimum
supply voltage and the scanner type.

CAUTION:
10 kW scanner systems cannot be used directly with 12 V
systems; they require a 12 V to 24 V converter rated to 180 W.
Contact your authorized Raytheon dealer or distributor for
details.

12 V Systems (4 kW scanners only)

For vessels with 12 V power systems, the recommended cable(s) for
different run lengths are given in the following table, which assumes
a minimum supply voltage of 10.7 V (the lowest voltage likely to be
reached by a 12 V battery in normal marine use). Do not use cable
combinations that are not included in the table.

Refer to the packing list in Section 1.2 for cable part numbers

24 V and 32 V Systems - 4 kW scanners

For vessels with 24 V and 32 V power systems, any combination of
inter-unit cable up to a maximum length of 35 m can be used.

Table 1-7: Recommended 4 kW Open Array Scanner Inter-Unit Cable(s)

for Vessels with 12 V Power Systems

Inter-Unit Cable
Length Required (m)

4 kW Scanners

5

5m heavy

15
15

15 m heavy
5 m heavy + 10 m extension

154_4.book Page 16 Wednesday, October 25, 2000 3:02 PM