OPERATING INSTRUCTIONS

GF55-008

AUGER TRIM

AUTO/OFF

HIGH/LOW

MANUAL

FAN

AUGER

ON/OFF

HEAT

LEVEL

1

2

3

4

5

6

7

8

9

1. AUGER TRIM:

Used to change feed rates on LOW ONLY for poorer quality fuels.
Push the Auger Trim button until the number 1 and 5 lights appear
on the Heat Level Indicator. This will increase the feed rate to 4
seconds ON time Auger pulse. This is done only on LOW to allow
the burning of poor quality fuels. Push the button until the number
1 and 4 lights appear, this will reduce the Auger On time to 2 sec-
ond. This setting is for high-grade fuel only. Push the button until
just the number 1 light is on, this is for a three (3) second on time
(standard setting).

2. CONVECTION BLOWER CONTROL:

Used to turn the convection blower ON/OFF. Leave the convection
blower ON for peak effi ciency.

3. AUGER PULSE LIGHT:

This light will fl ash in conjunction with the auger. The light comes
on when auger turns.

4. MANUAL AUGER FEED:

If the unit runs out of fuel, this button can be used to “prime the
auger system”. This button will turn off after 60 seconds and then
must be released and pressed again.

5. SYSTEM LIGHT:

Responsible for signaling the state of the control board. When
the light is fl ashing during start-up, the stove is in an automatic
start mode. When the light is solid, the Heat Level Setting can be
altered.

6. ON/OFF BUTTON:

Used to turn the unit ON and OFF.

7. HEAT LEVEL ADJUSTMENT:

When pressed, will change the heat setting of the unit from low to
high.

8. HEAT OUTPUT INDICATOR:

Shows the present heat output setting.

9. CONTROL MODE SWITCH:

Used to set the unit’s controls to one of three mode settings; manual,
high/low, or auto/off.

CONTROL BOARD FUNCTIONS

AUTOMATIC SAFETY FEATURES

A. The stove and insert have a low limit safety switch located on the housing of the exhaust blower. If the exhaust temperatures drop below 120°F

(49°C) the unit will shut down and will be required to go through a full start up procedure again.

The most common cause for this is an empty hopper. This switch should only be by-passed for testing purposes by a technician.

B. The stove and insert have a high limit safety switch located just below the hopper behind the external body panels. If the temperature of this

switch reaches 200°F (93°C), the auger will stop feeding fuel and as the exhaust temperatures drop below 120°F (49°C), the unit will shut
down.

The 200°F (93°C) switch is a manual reset and should only be reset by a service person who can first diagnose the reason for failure.

The two most likely causes are Convection Fan failure or High Limit Switch failure. Either one needs to be properly diagnosed and rectified.

Since this is a safety switch it should never be by-passed for any reason other than the service technician to test the operation.