OPERATING INSTRUCTIONS

Figure 4: Thermostat Switch in

MANUAL position.

Figure 5: Thermostat Switch in HIGH/LOW position.

















Figure 6: Thermostat Switch in ON/OFF position.









OPERATING YOUR PELLET STOVE

PRE-BURN INSTRUCTIONS:

The burn pot liner holes must be clear and the liner installed properly against the ignitor tube for proper

operation. Check the hopper for enough pellets to start the unit.

Note: The thermostat mode can be changed during normal operation.

DO NOT OPERATE THE UNIT WITH THE DOOR OR ASH PAN OPEN.

MANUAL MODE

(No thermostat)

All control of circuit board function is adjusted at the circuit board.

START-UP: Press the ON / OFF button. The stove will turn on. The system
light will fl ash. The Auger Light will fl ash with each pulse of the auger (the
Auger Feed Rate is pre-programmed during start-up). The Heat Level
Indicator will show the Heat Level that the stove will run at after start-up.

If this is the first time the unit has been started or the unit has run out of
fuel, the auger will need to be primed. Press the Manual Auger Feed
button until fuel starts to drop into the Burn Pot Liner. See "Control Board
Functions" section.

OPERATION: When a fire has been established, the System Light will
turn solid (after approximately 10 - 15 minutes) and the Auger Light will
continue to flash to the corresponding Heat Level setting. The Heat Level
button can now be pressed at this time to change the desired Heat Level
Output setting.

The convection blower (room air blower) will turn on. The speed of this
blower is controlled by the setting of the heat level output indicator. The
convection blower can be turned OFF by depressing the convection
blower control button. For the best efficiency and to prevent cycling, the
convection blower should be left on at all times.

When operating on LOW HEAT LEVEL, the feed rate can be adjusted,
using the auger trim, for different quality fuels. These settings can be
used if the fire keeps going out on low (poor quality fuel). Or if the low
setting is too hot for the room. See "Control Board Functions" section.

TURNING OFF: To turn the unit OFF, simply press the ON / OFF button.
This will stop the feed of pellets. The blowers will continue to operate and
cool the stove down. When cool enough, the stove will turn off.

DO NOT unplug unit while Combustion fan is operating.
This may lead to smoke escaping from the stove.

HIGH / LOW MODE

(Requires a thermostat)

INITIAL START-UP: See "manual mode".

OPERATION: When the thermostat calls for heat (contacts are closed) the
stove settings are adjustable as per Manual Mode. When the thermostat
contacts open, the HEAT LEVEL and Fans will drop down to the LOW
setting until the thermostat contacts close again. *The LOW heat setting
can be adjusted for different fuel qualities (see "Control Board Functions"
section). The stove will come back to the previous HEAT LEVEL setting
when the thermostat contacts close again.

TURNING OFF: To turn the unit OFF, simply press the ON / OFF button.
This will stop the feed of pellets. The blowers will continue to operate and
cool the stove down. When cool enough, the stove will turn off.

DO NOT unplug unit while Combustion fan is operating.
This may lead to smoke escaping from the stove.

AUTO / OFF MODE

(Requires a thermostat)

INITIAL START-UP: See "manual mode".

OPERATION: When the thermostat contacts close, the unit will light
automatically. Once up to temperature, the stove operates the same
as in MANUAL. When the thermostat contacts open, the stove’s HEAT
LEVEL and Fans will drop down to the LOW setting for 30 minutes. If the
thermostat contacts close within the 30 min, the HEAT LEVEL will return
to the previous MANUAL setting. If the thermostat contacts remain open
the stove automatically begins its shutdown routine. The stove will re-
light when the thermostat contacts close again.

TURNING OFF: To turn the unit OFF, turn the thermostat down or off.

DO NOT unplug unit while Combustion fan is operating.
This may lead to smoke escaping from the stove.