Notice, Maintenance (continued), Danger – RIDGID OF45150 User Manual

Page 8: Maintenance schedule

Advertising
background image

1. When not in use, compressor should be

stored in a cool dry place.

2. Tank should be drained of moisture.

3. Hose should be disconnected and hung

open ends down to allow any moisture
to drain.

15

3. Daily with compressor shut off:

Depressurize system prior to draining
tank. Drain moisture from tank by
opening the tank drain valve under-
neath the tank.

4. Turn power OFF and clean dust and

dirt from motor, tank, air lines and
pump cooling fins.

NOTE: The air filter in the filter housing
on the side of the head must be checked
and cleaned periodically, more often if
used under very dusty conditions or
when a great deal of fog from spraying is
allowed to circulate near unit.

IMPORTANT: Unit should be located as
far from spraying area as hose will allow
to prevent over-spray from clogging filter.

Maintenance (Continued)

14

Safety valve must be replaced if
it cannot be actuated or it leaks
air after ring is released.

!

WARNING

Tank
Drain
Valve

The tank should be carefully inspected at
a minimum of once a year. Look for
cracks forming near the welds. If a crack
is detected, remove pressure from tank
immediately and replace.

Tank

Never attempt to repair or modi-
fy a tank! Welding, drilling or
any other modification will
weaken the tank resulting in
damage from rupture or explo-
sion. Always replace worn,
cracked or damaged tanks.

!

DANGER

Drain liquid from tank daily.

NOTICE

To change a filter, pull off the filter housing
cover. If filter element is dirty, replace ele-
ment or entire filter.

Filter Removal, Inspection and Replacement

This is an oilless type compressor requir-
ing no lubrication.

Lubrication

Storage

Operation

Daily

Weekly

Drain Tank

Check Air Filter

Check Safety Valve

Blow Dirt From Inside Motor

Maintenance Schedule

Figure 7

Advertising