Troubleshooting

16

For your own safety do not try
and run the air compressor
while troubleshooting.

!

WARNING

TROUBLE

PROBABLE CAUSE

REMEDY

Compressor will not
run

Motor hums but can-
not run or runs slow-
ly

Fuses blow/circuit
breaker trips repeat-
edly

1. Unit is plugged into

extension cord

2. No electrical power

3. Blown fuse
4. Breaker open

5. Thermal overload open
6. Pressure switch bad

1. Low voltage
2. Unit is plugged into

extension cord

3. Shorted or open motor

winding

4. Defective check valve or

unloader

1. Incorrect size fuse, circuit

overloaded

2. Unit is plugged into

extension cord

3. Defective check valve or

under loader

1. Remove extension cord

2. Plugged in? Check

fuse/breaker or motor over-
load

3. Replace blown fuse
4. Reset, determining why

problem happened

5. Motor will restart when cool
6. Replace

1. Check with voltmeter
2. Remove extension cord

3. Replace motor

4. Replace or repair

1. Check for proper fuse, use

time-delay fuse.
Disconnect other electrical
appliances from circuit or
operate compressor on its
own branch circuit

2. Remove extension cord

3. Replace or repair

TROUBLE

PROBABLE CAUSE

REMEDY

Thermal overload
protector cuts out
repeatedly

Air receiver pressure
drops when com-
pressor shuts off

Excessive moisture
in discharge air

Compressor runs
continuously

Compressor vibrates

Air output lower than
normal

1. Low voltage
2. Clogged air filter

3. Lack of proper ventila-

tion/room temperature
too high

4. Unit is plugged into

extension cord

1. Loose connections (fit-

tings, tubing, etc.)

2. Loose drain lock
3. Check valve leaking

1. Excessive water in air

receiver

2. High humidity

1. Defective pressure

switch

2. Excessive air usage

Loose mounting bolts

1. Broken inlet valves

2. Intake filter dirty

3. Connections leaking

1. Check with voltmeter
2. Clean filter (see

Maintenance section)

3. Move compressor to well

ventilated area

4. Remove extension cord

1. Check all connections with

soap and water solution
and tighten

2. Tighten
3. Disassemble check valve

assembly, clean or replace

Do not disassemble
check valve with air in
tank; bleed tank

1. Drain receiver

2. Move to area of less

humidity; use air line filter

1. Replace switch

2. Decrease air usage; com-

pressor not large enough
for a requirement

Tighten

1. Have authorized service

representative repair unit

2. Clean or replace intake fil-

ter

3. Tighten connections

!