Roberts Gorden CTH2-125 User Manual

Page 14

Advertising
background image

CTH2-S

ERIES

I

NSTALLATION

, O

PERATION

AND

S

ERVICE

M

ANUAL

8

NOTE: 1. All dimensions are from the surfaces of all tubes, couplings and elbows.

2. Clearances B, C and D can be reduced by 50% after 25' (7.5 m) of tubing downstream
from where the burner and burner tube connect.

*When installed in the first 10' (3 m).

FIGURE 10: 2-FOOT DECO GRILLE AND PROTECTIVE GRILLE

(inches)

(centimeters)

Model

A

B

C

D

A

B

C

D

CTH2-40

6

27

53

27

16

69

135

69

CTH2-60

6

35

63

35

16

89

161

89

CTH2-80

6

38

66

38

16

97

168

97

CTH2-100

6

40

71

40

16

102

181

102

CTH2-125

6

46

77

46

16

117

196

117

CTH2-150

6

50

80

50

16

127

204

127

CTH2-175

8

52

82

52

21

133

209

133

A

C

D

B

FIGURE 11: LOWER CLEARANCE SHIELD*

(inches)

(centimeters)

Model

A

B

C

D

A

B

C

D

CTH2-40

6

34

27

34

16

87

69

87

CTH2-60

6

39

33

39

16

100

84

100

CTH2-80

6

40

38

40

16

102

97

102

CTH2-100

6

50

44

50

16

127

112

127

CTH2-125

6

54

48

54

16

138

122

138

CTH2-150

6

55

50

55

16

140

127

140

CTH2-175

- UNAPPROVED -

- UNAPPROVED -

A

C

D

B

FIGURE 12: VENTING

(inches)

(centimeters)

Model

A

E

F

A

E

F

CTH2-40

14

18

18

36

46

46

CTH2-60

14

18

18

36

46

46

CTH2-80

20

24

18

51

61

46

CTH2-100

20

24

18

51

61

46

CTH2-125

20

24

18

51

61

46

CTH2-150

20

30

18

51

77

46

CTH2-175

20

30

18

51

77

46

Radiant Tubes

Vent

Pipes

Unvented

Vented

A

E

F

Advertising
This manual is related to the following products: