RF-Link NL6000 User Manual

Page 28

Advertising
background image

RF Neulink

NL6000 User Guide

28

6.1.

General Procedures

Entering Programming Mode

Perform this procedure when you need to reset any of the existing
configuration parameters for the NL6000.

Note: If the Programming Mode is Disabled, you must perform
this procedure within five seconds of powering on the unit.

1. Open HyperTerminal or Procomm.

2. Type …//

The Main Menu opens.

Setting the Program Mode

The

Program Mode

parameter determines when the operator can enter

programming mode from operational mode.

1. Select Serial

ä Program Mode.

2. Select from the following options:

1-Disabled

Enter programming mode within five seconds of power-on.

Select this option under normal operating conditions to
prevent accidental resetting of parameters.

2-Enabled

Enter programming mode whenever you type the key

sequence …// . There must be a pause before and after the
sequence. Select this option during factory configuration or
during initial configuration of a unit.

Saving Configuration Changes to Flash Memory

Select E - Exit from the Main Menu to save the updated parameter settings to
the unit s flash memory. The unit immediately begins using the new
configuration.

Saving Configuration Changes Temporarily

Select C - Continue from the Main Menu to temporarily save the updated
settings for the current operating session. The configuration is not saved to
flash memory. You can revert to the prior configuration by cycling power to the
unit.

Reverting to the Prior Configuration

Select R - Restart from the Main Menu to ignore the changes you made and
revert back to the prior configuration.

Advertising