3 serial connection setup – RF-Link NL6000 User Manual

Page 31

Advertising
background image

RF Neulink

NL6000 User Guide

31

6.3

Serial Connection Setup

Setting the Baud Rate

1.

Select

Serial

ä

Baud Rate

.

2.

Select a baud rate for the connection between the modem and I/O device.
The options range from 1200 to 38400.

Setting the Data Bits

1.

Select

Serial Data Bits

.

2.

Select the number of data bits per byte sent from the I/O device. The
options are

7

or

8

bits per byte.

Setting the Stop Bits

1.

Select

Serial

ä

Stop Bits

.

2.

Select the number of number of bits used to designate the end of a
byte. The options are

1

or

2

bits.

Setting the Transmit Character Timeout

1.

Select

Serial

ä

Transmit Character Timeout

.

2. Enter the expected pause between data strings through the serial port.

The value must be in the range 10

9999 milliseconds.

Setting the Flow Control Option

1.

Select Serial

ä Flow Control.

2.

Select from the following options:

1-None

Do not use flow control.

2-RTS/CTS

Monitor the Ready To Send (RTS) signal to determine

when to send data to the serial device and assert CTS to
tell the serial device when it can send data to the
modem.

3-XON/XOFF Use special ASCII characters to determine when to

send/receive data to/from the serial device.

Setting the DCD Mode

1.

Select Serial

ä DCD Mode.

2.

Select from the following options:

1-Enable

In this mode the modem asserts the DCD line when it is

receiving data over-the-air.

2-Disable

In this mode the modem asserts the line when it is in a

normal operating state and negates the line when it is in a
programming state.