Provision of ventilation, Location of cooker – Rangemaster Toledo 90 Gas User Manual

Page 23

Advertising
background image

23

You must be aware of the following
safety requirements & regulations

Prior to installation, ensure that the local distribution

conditions (nature of the gas and gas pressure) and

the adjustment of the appliance are compatible.

This appliance shall be installed in accordance with

the regulations in force and only in a well ventilated

space. Read the instructions before installing or using

this appliance.

In the UK the regulations and standards are as

follows:-

In your own interest and that of safety, it is law that all

gas appliances be installed by competent persons.

CORGI registered installers undertake to work to safe

and satisfactory standards. Failure to install the

appliance correctly could invalidate any warranty or

liability claims and lead to prosecution. The cooker

must be installed in accordance with

All relevant British Standards / Codes of
Practice, in particular BS 5440 Part 2 2000,

For Natural Gas - BS 6172 : 1990 and BS
6891 : 1998

For LP Gas - BS 5482-1:1994 (when the
installation is in a permanent dwelling), BS
5482-2:1977, (when the installation is in a
caravan or other non permanent dwelling),
or BS 5482-3:1999 , (when the installation
is in a boat).

The Gas Safety (Installation and Use)
regulations 1998.

The relevant Building / IEE regulations.

Provision of Ventilation

This appliance is not connected to a combustion

products evacuation device. Particular attention shall

be given to the relevant requirements regarding

ventilation.

The room containing the cooker should have an air

supply in accordance with BS 5440 Part 2 : 2000. All

rooms require an openable window or equivalent,

while some rooms require a permanent vent in

addition to the openable window. The cooker should

not be installed in a bedsitting room with volume less

than 20m

3

. If it is installed in a room of volume less

than 5m

3

an air vent of effective area 100cm

2

is

required; if it is installed in a room of volume between

5m

3

and 10m

3

, an air vent of effective area 50cm

2

is

required; while if the volume exceeds 11m

3

, no air

vent is required.

If there are other fuel burning appliances in the same

room, BS 5440 Part 2 : 2000 should be consulted to

determine the requisite air vent requirements.

Location of Cooker

The cooker may be installed in a kitchen/kitchen diner

but NOT in a room containing a bath or shower.

NOTE:

An appliance for use on LPG shall not be installed

in a room or internal space below ground level.

e.g. in a basement.

This appliance is designed for domestic cooking only.

Use for any other purpose could invalidate any

warranty or liability claim.