Specifications – Rinnai R98LSI User Manual

Page 3

Advertising
background image

VB Series Indoor LS Manual

3

Specifications

Rinnai is continually updating and improving products. Therefore, specifications are subject to change without
prior notice.

The maximum inlet gas pressure must not exceed the value specified by the manufacturer. The minimum value
listed is for the purpose of input adjustment.

Model

RL75i

RL94i

R98LSi

R98LSi-ASME

Minimum Gas Consumption Btu/h

9,900 (NG)

10,300 (LPG)

19,000

Maximum Gas Consumption Btu/h

180,000

199,000 (NG)

190,000 (LP)

237,000

Hot water capacity (Min - Max) *

0.4 - 7.5 GPM

(1.5 - 28.5 L/min)

0.4 - 9.4 GPM

(1.5 - 35.5 L/min)

0.6 - 9.8 GPM

(2.4 - 37 L/min)

Hot water capacity (45°F rise)

6.6 GPM

(25.0 L/min)

7.1 GPM

(27.0 L/min)

8.5 GPM

(32.2 L/min)

Default Temperature Setting (no controller)

120º F (49º C)

Temperature Controller Default Setting

104º F (40º C)

Maximum Temp Setting (commercial **)

160º F (71º C)

185º F (85º C)

Maximum Temp Setting (residential)
see Temperature Ranges for more information

Selectable at 120º F (49º C) or at 140º F

(60º C)

140º F (60º C)

Minimum Temperature Setting

98º F (37º C)

Weight

51 lb (23 kg)

53 lb (24 kg)

55 lb (25 kg)

Efficiency

Thermal Efficiency: 84.0%

Noise level

49 dB

Electrical Consumption

Normal

76 W

83 W

99 W

Standby

2 W

Anti-frost Protection

184 W

116 W

By-Pass Control

Fixed

Electronic

Minimum Gas Supply
Pressure

Natural Gas

5.0 inch W.C.

Propane

8.0 inch W.C.

Maximum Gas Supply
Pressure

Natural Gas

10.5 inch W.C.

Propane

13.5 inch W.C.

Type of Appliance

Direct Vent, Temperature controlled continuous flow gas hot water system.

Operation

With or without remote controls, mounted in kitchen, bathroom, etc.

Approved Gas Type

Natural Gas or Propane - Ensure unit matches gas type supplied at the installation

Connections

Gas Supply: 3/4" MNPT, Cold Water Inlet: 3/4" MNPT, Hot Water Outlet: 3/4" MNPT

Ignition System

Direct Electronic Ignition

Electric Connections

Appliance: AC 120 Volts, 60Hz. Remote Control: DC 12 Volts (Digital)

Water Temperature Control

Simulation Feedforward and Feedback.

Water Supply Pressure

Minimum Water Pressure: 20 PSI (Recommended 30-80 PSI for maximum

Maximum Water Supply Pressure

150 PSI

Remote Control Cable

Non-Polarized Two Core Cable (Minimum 22 AWG)

Energy Star Qualified

Yes

Yes

No (not applicable)

Certified for installation in manufactured (mobile)
homes

Yes

Yes

No

No

Energy Factor: 0.82

* Minimum flow may vary slightly depending on the temperature setting and the inlet water temperature.

** for commercial and hydronic applications requiring higher temperatures