9. Maintenance

English

PROCEDURES TO BE PERFORMED AFTER

EVERY 100 HOURS OF USE

1. Remove the muffler, insert a screwdriver into the

vent, and wipe away any carbon buildup. Wipe away
any carbon buildup on the muffler exhaust vent and
cylinder exhaust port at the same time.

2. Tighten all screws, bolts, and fittings.

AIR INLET NET

• Blowing air is taken in from the air inlet net. When air

flow has dropped down during operation, stop the
engine and inspect the air inlet net for blocking by
obstacles.

• Note that failure to remove any such obstacles may

result in the engine becoming overheated and
damaged.

(1) Net

Never use the blower without the net of the blower.
Before each use, check that the net is attached in
place and is free from any damage.

IGNITION COIL AIR GAP INSPECTION
• If the gap is out of standard or when installing the

coil or rotor, adjust the air gap between the ignition
coil and the iron core of the rotor.

Air Gap:

0.40mm (0.35 ~ 0.45mm)
0.016" (0.014 ~ 0.017")

(1) Rotor
(2) Ignition coil