Application, 2 interrupts – Renesas 4514 User Manual

Page 120

Advertising
background image

APPLICATION

2.2 Interrupts

2-17

4513/4514 Group User’s Manual

(6)

Timer 4 interrupt
Constant period interrupts by a setting value to timer 4 can be used.

Outline: The constant period interrupts by the timer 4 underflow signal can be used.
Specifications: Prescaler, timer 3 and timer 4 divide the system clock frequency f(X

IN

) = 4.0 MHz,

and the timer 4 interrupt occurs every 250 ms.

Figure 2.2.8 shows a setting example of the timer 4 constant period interrupt.

Fig. 2.2.1 INT0 interrupt operation example

P3

0

/INT0

P3

0

/INT0

“H”

“H”

“L”

“L”

An interrupt occurs after the valid waveform “falling” is detected.
An interrupt occurs after the valid waveform “rising” is detected.