APPLICATION

2.2 Interrupts

2-23

4513/4514 Group User’s Manual

Fig. 2.2.7 Timer 3 constant period interrupt setting example

g0 h

0

b3

b0

Disable Interrupts

Timer 3 interrupt is temporarily disabled.

Interrupt enable flag INTE

Interrupt control register V2

“0”

All interrupts disabled (DI instruction)

Timer 3 interrupt occurrence disabled
(TV2A instruction)

b3

b0

0 1

Stop Timer 3 Operation

Timer 3 and prescaler are temporarily stopped.
Dividing ratio of prescaler is selected.

Timer control register W1

Prescaler stop (TW1A instruction)
Prescaler divided by 16 selected

Timer 3 stop (TW3A instruction)
Prescaler selected for count source

b3

b0

0

1

0

Timer control register W3

Set Timer Value

Timer 3 count time is set. (The formula is shown

A below.)

Timer 3 reload register R3

“52

16

Timer count value 82 set (T3AB instruction)

Clear Interrupt Request

Timer 3 interrupt activated condition is cleared.

Timer 3 interrupt request flag T3F “0”

Timer 3 interrupt activated condition cleared
(SNZT3 instruction)

Note when the interrupt request is cleared

When

is executed, considering the skip of the next instruction according to the

interrupt request flag T3F, insert the NOP instruction after the SNZT3 instruction.

b3

b0

0

1

1

Start Timer 3 Operation

Timer 3 and prescaler temporarily stopped are restarted.

Timer control register W3

Timer 3 operation start (TW3A instruction)

Prescaler operation start (TW1A instruction)

b3

b0

1 1

Timer control register W1

✕ ✕

b3

b0

1

Enable Interrupts

The timer 3 interrupt which is temporarily disabled is enabled.

Interrupt control register V2

Interrupt enable flag INTE

“1”

Timer 3 interrupt occurrence enabled
(TV2A instruction)
All interrupts enabled (EI instruction)

Constant period interrupt execution start

A The prescaler dividing ratio and time 3 count value to make the interrupt occur every 1 ms are set as follows.

1 ms

(4.0 MHz)

3

16

(82+1)

–1

System clock Instruction

clock

Prescaler
dividing
ratio

Timer 3
count
value

”: it can be “0” or “1.”