Two-speed pumps, Pilot safety, Start – Raypak RAYTHERM P-926 User Manual

Page 24: Procedure, Before start-up, Start-up, Start-up procedures, Servicing, General location of controls, Temperature control

Advertising
background image

24

SERVICING

General Location Of Controls

Models 926-1826

Models 2100-4001

Temperature Control

The pool water temperature is controlled by the pool

thermostat. The heater water temperature high limit is

controlled by the manual reset high limit.

Pressure Switch

The pressure switch, or heater actuator on Models

926-1223 equipped with a Unitherm Governor,

ensures that the heater operates only when the filter

pump is in operation. It is factory set at 1.75 PSI for

deck level installations. When the heater is located

below the level of the spa or pool, it may be necessary

to reset the pressure switch to compensate for the no-

flow static head. If it is necessary to reset the pressure

switch, we recommend the following procedure.

Pressure Switch Adjustment

1. Make sure the pool filter is clean before adjusting

the switch.

2. Set the heater control to the OFF mode.

3. Turn the filter pump on and confirm that the pres-

sure switch is closed (use a multimeter to check).

If the pressure switch fails to close, either the

switch setting is too high or the filter pump is not

supplying enough pressure.

4. Turn the heater ON.

5. Manually turn the pressure adjustment knob clock-

wise until the heater shuts off. (A flat screw driver

may be necessary if knob is too tight).

6. Slowly turn the adjustment knob counter-clock-

wise until the heater calls for heat again.

7. Turn an additional 1/2 turn counter-clockwise.

8. While the heater is running, check the adjustment

by turning the pump off and on several times. The

burners should shut off immediately when the

pump is turned off. If it does not, repeat the above

steps until proper operation is observed.

t

e

lt

u

O

/t

e

l

n

I

Pressure

r

e

d

a

e

H

Switch

m

r

e

h

ti

n

U

Electrical

r

o

n

r

e

v

o

G

Conn.

Hi-limit
control/

e

v

l

a

V

s

a

G

r

e

n

r

u

B

n

i

a

M

l

o

r

t

n

o

C

.

p

m

e

T

Fig. 28: General Location of Controls

(Models 926-1826)

Inlet/Outlet
Header w/Bypass
Pump

Electrical

Connection

Main Burner

Gas Valve

Manual On/Off Valve

Fig. 29: General Location of Controls

(Models 2100-4001)

Advertising
This manual is related to the following products: