5.3 Rear Movable Hanger Limits

Figure 8 shows a typical installation of the CGTH-
Series heater. The drawing specifies the allowable
range of distance between the front fixed hanger and
the rear movable hanger.

The rear hangar should only be moved if the distance
between both hangers is not within the allowable
range.

FIGURE 8: Typical Installation

1" (3 cm)

Maximum

6" (15 cm) Minimum

Vent Terminal

Exterior Wall

Burner Box

Reflector

Suspension

Points

Minimum

Recommended

for Servicing

Minimum Mounting

Height - 7' (2.1 m)*

24"

(61 cm)

15"

(38 cm)

X

X Dimension

Model

Minimum

Maximum

CGTH-30

60" (1.5 m)

72" (1.8 m)

CGTH-40

102" (2.5 m)

114" (2.9 m)

CGTH-50

102" (2.5 m)

114" (2.9 m)

(*) For minimum mounting height in aircraft
hangars and public garages,

See Page 7

,