TABLE A-5 BELT DRIVE BLOWER SET-UP

Blower Set-Up

Model

HO-B

0.20 in. w.c.

0.50 in. w.c.

Cooling Capacity

Pulley Pulley

Bonnet Output

(BTUH)

Blower

Motor

hp

Fan Belt

Blower Motor Turns

Out

Blower Motor Turns

Out

Tons CFM

Range

80 (60,000)

3 2

80 (70,000)

2 1

80 (80,000)

G10

½

4L360

5 x ¾

3¼ x ½

2

5 x ¾

3¼ x ½

1

3

1000 - 1300

120 (90,000)

3 2

120 (100,000)

3 1

120 (120,000)

G10

½

4L360

5 x ¾

3¼ x ½

2

5 x ¾

3¼ x ½

0

3

1000 - 1500

TABLE A-6 BELT DRIVE BLOWER CHARACTERISTICS

CFM

External Static Pressure - inches w.c.

Furnace

Model

Motor

hp

Blower

Temp.

Rise

(

DT)

Motor

FLA

Motor

Pulley

Turns Out

0.20 0.30 0.40 0.50 0.60 0.70

0

1596 1518 1435 1330 1247 1184

1

1505 1434 1347 1220 1081 993

2

1567 1453 1291 1125 996 817

80F

½

G10

60° - 90°F

5.8

3

1429 1332 1180 1064 818 558

0

1832 1747 1658 1546 1446 1338

1

1694 1603 1507 1382 1245 1119

2

1566 1467 1339 1196 1064 880

120F

½

G10

55° - 85°F

5.8

3

1383 1270 1120 1006 771 545

TIP:

These formulae will assist with the design of the ductwork and the determination of airflow delivery:

(

)

(

)

CFM

Bonnet Output

x SystemTemperature Rise

SystemTemperature Rise

Bonnet Output

xCFM

=

=