Rinnai RHFE-431FA User Manual

Page 9

Advertising
background image

– 7 –

Safety Devices

Noise Level Range

HI

LOW

38

32dB(A)

TYPE

SPECIFICATIONS FOR VENT SIZES

S

Thin Walls Mobile Home

Wood Walls

Wood/Brick

Brick/Block

Special

3"

4 1/2"

(75

115)mm

4 1/2"

9 1/2"

(115

240 )mm

9 1/2"

15 3/4"

(240

400 )mm

15 3/4"

23 5/8"

(400

600 )mm

23 5/8"

31 1/2"

(600

800 )mm

A

B

C

D

(80mm) 3 1/8"

(4m, 2 bends)

13ft., 2 bends

Combustion Method

Air Supply Exhaust

Radiation Method

Forced combustion

Closed Type

Forced convection

Wall Penetration

Hole

Max. Extended

AIR SUPPLY/
EXHAUST PIPE

Flame failure – Flame rod
Over heat – Bi-metal switch, thermal fuse, thermistor
Power failure – PCB
Power surge – 3 Amp. fuse
Fan delay – Micro computer timer
Pre-purge – Combustion fan, pre-purge timer, spark sensor
Room over heat – Automatic cut off at 104°F after 10 minutes

** BTU - Efficiency increase with vent size. Clearances from combustibles see pages 3 and 19.
** Thermal efficiency rating determined under continuous operating conditions, and was determined

independently of any installed system.

Advertising