Repeated playback of phrases (interval playback), Operational specifications of interval playback, Ar-200 settings – Roland AR-200 User Manual

Page 34: What is terminal rec/use and applications, P. 34)

Advertising
background image

34

Controlling the AR-200 from an External Device (Control Input Connectors)

Repeated Playback of

Phrases (Interval Playback)

The specified phrase will be played back at fixed intervals.
Make each of the terminal settings beforehand for the
playback interval and phrases to be played back.

When making settings in Interval Playback mode, assign
Phrases 1 through 9 to the control output connectors 1
through 9.

The playback interval settings are shown below.

Port No.

Playback Interval

1

1 second

2

5 seconds

3

10 seconds

4

15 seconds

5

30 seconds

6

1 minute

7

5 minutes

8

15 minutes

9

30 minutes

Operational Specifications of
Interval Playback

Basic Operation of Interval Playback

fig.inp-21

[Interval time used for phrases]

Playback:

Input control signals to the control Input/output connectors
No. 1 through 9.

Results in the repeated play of the phrase assigned to the

terminal.

stopping:

Input a control signal to Port No. 10 (STOP).

This stops playback of the phrase.

AR-200 Settings

Selecting the Control Input Mode

Set the MODE switches on the AR-200’s bottom panel to
select “INTERVAL PLAYBACK” from the control input

modes (PLAYBACK BY CARD DATA/DIRECT
PLAYBACK/BINARY PLAYBACK/INTERVAL
PLAYBACK).

You cannot achieve control input playback merely by
connecting a device to the port. Be sure to set the control
input mode and match the method used for connecting to the
connectors.

Procedure for Setting the Control Input Mode

1.

Turn off the power of the AR-200.

2.

Set the MODE switches on the AR-200’s bottom panel as
shown below.

SW1: ON

SW2: ON

3.

Turn on the power of the AR-200.

* Use a pointed object to change the ON/OFF settings of the

MODE switches.

Controlling Recording with
the Control Connectors

(Terminal Rec)

What is Terminal Rec/Use and
Applications

You can specify phrases by inputting binary (base 2) signals
to the Port Nos. 1 through 8, and perform record, playback,
and erase functions by inputting control signals to Port Nos.
9 and 10. A total of 250 phrases can be specified with control
signals (On/Off). This is convenient when you want to
control recording from an external control device.

fig.inp-22

[Signal sent to Port Nos. 9 and 10]

* To conduct binary control, you need to provide a control

device that can generate binary signals.

* Input of binary specifications should be completed in no more

than 50 milliseconds.

0002

AUDIO OUTPUT

Port No. 2

STOP Port

0002

0002 interrupted

Interval time used for phrases

Binary Specification

01110000

Phrase112

Record

Play

Delete

8 7 6 5 4 3 2 1

Signal sent to Port

Nos. 9 and 10

Port 1--8

AR-200_e.book 34 ページ 2003年7月14日 月曜日 午後1時11分