Chapter 7 analyzing your data – RayTek ThermoView Ti30 User Manual

Page 55

Advertising
background image

Chapter 7 Analyzing Your Data

There are many ways to analyze your thermal data now that you have it downloaded and
organized. After clicking on a thumbnail in the Main InsideIR screen, the data for that
specific thermal image is displayed in one of four tabs: Image, Temperature Table, Profile,
and Histogram.

While each of these analytical tools possess unique qualities, they also share many features.
For example, data from any of the tabs may be saved in other formats or cut and pasted into
other applications for your own further analysis or communications needs. The four tabs
also share many commands on the menu bar, which will be explained at the end of this
chapter.

InsideIR allows you to open many windows at one time. Keep in mind that functions on the
menu bar are always associated with the active window.

The Single Image Screen

Clicking any of the thumbnail images in the Main InsideIR screen takes you to the Image
tab for that image. On this screen, you can view basic data about the image.

Clicking on any part of the image will display the temperature reading at that spot (indicated
by the crosshatch). You may click as many spots as you wish, with each click adding a
reading to the displayed image. To erase the displayed temperature points, simply click while
moving your mouse. Clicking and dragging around the image will momentarily display the
temperature reading on points along your path.

Scale Limits

When the Scale Limits radio button at the bottom of the Image screen is selected, the limit
bar underneath the image shows the temperature range your ThermoView Ti30 imager is
capable of measuring. The minimum (0º C / 32º F) is represented at the far left of the bar,
and the maximum (250º C / 482º F) is represented by the far right of the bar. The red area
on the bar indicates the range of temperatures, within the minimum and maximum limits,
that are represented in the thermal scene.

In order to see more detail in narrow ranges of temperature, it is often useful to adjust the
scale limits. In order to do this, make sure the Scale Limits radio button is selected. To
adjust the upper or lower limits, click and drag the appropriate arrow at the edge of the red
portion of the bar. To keep the same range span but change the limits, you can drag the
whole red section of the bar left (colder) or right (warmer).

To go back to the original scale, double-click on the scale bar.

July 1, 2003

- 55 -

Version 1.0

i

i

Tel: (01943) 602001- WWW.ISSLTD.CO.UK - Fax: (01943) 816796

Advertising