Specifications, Operating environment, Power supply specifications – RuggedCom RS900GP User Manual

Page 17: General, Ieee802.3af, Ieee802.3at, Failsafe relay specifications, 17 3.2. power supply specifications, 17 3.2.2. ieee802.3af, 17 3.2.3. ieee802.3at

Advertising
background image

3. Specifications

RuggedCom® RuggedSwitch™

17

RS900GP Installation Guide Rev 101

3. Specifications

3.1. Operating Environment

Parameter

Range

Comments

Ambient Operating Temperature

-40 to 85°C

Ambient Temperature as measured
from a 30cm radius surrounding the

center of the RS900GP enclosure.

Ambient Relative Humidity

5% to 95%

Non-condensing

Ambient Storage Temperature

-40 to 85°C

Operating Altitude

0 to 15240m (0 to 50000 ft)

Over temperature range of -40 to 85°C

Table 3.1. Operating Environment

3.2. Power Supply Specifications

3.2.1. General

Power

Supply Type

Minimum Input

Maximum Input

Fuse Rating

Isolation

RS900GP

Maximum

Power

Consumption

Maximum

Combined

Power Output

at PoE Ports

54 VDC

45 VDC

57 VDC

6.3A (T)

a

1.5 kV DC

15W

273W

a

(T) denotes time-delay fuse

Table 3.2. RS900GP Power Supply Specifications

3.2.2. IEEE802.3AF

Power In

Power Out

45-57 VDC, 3.5 A MAX

44-57 VDC, 15 W/PORT MAX

Table 3.3. IEEE802.3AF Power Supply Ratings

3.2.3. IEEE802.3AT

Power In

Power Out

51-57 VDC, 6 A MAX

50-57 VDC, 30 W/PORT MAX

Table 3.4. IEEE802.3AT Power Supply Ratings

3.3. Failsafe Relay Specifications

Parameter

Value

Max Switching Voltage

30VAC, 80VDC

Rated Switching Current

0.3A @ 30VAC

1A @ 30VDC, 0.3A @ 80VDC

Table 3.5. Failsafe Relay Specifications

• Resistive Load.

• For Class-2 circuits only.