3. Specifications

RuggedCom® RuggedSwitch™

21

RS900GP Installation Guide Rev 101

3.7. Type Test Specifications

3.7.1. IEC 61850-3 Type Tests

Test

Description

Test Levels

Severity

Levels

Enclosure Contact

+/- 8kV

4

IEC 61000-4-2

ESD

Enclosure Air

+/- 15kV

4

IEC 61000-4-3

Radiated RFI

Enclosure ports

20 V/m

x

Signal ports

+/- 2kV @ 2.5kHz

x

D.C. Power ports

+/- 2kV

4

IEC 61000-4-4

Burst (Fast Transient)

Earth ground ports

+/- 2kV

4

Signal ports

+/- 2kV line-to-earth,

+/- 1.5kV line-to-line

4

IEC 61000-4-5

Surge

D.C. Power ports

+/- 1.5kV line-to-earth,

+/- 1kV line-to-line

3

Signal ports

10V

3

D.C Power ports

10V

3

IEC 61000-4-6

Induced (Conducted) RFI

Earth ground ports

10V

3

IEC 61000-4-8

Magnetic Field

Enclosure ports

40 A/m continuous,

1000 A/m for 1 s

N/A

IEC 61000-4-29

Voltage Dips & Interrupts

D.C. Power ports

30% for 0.1s, 60% for

0.1s, 100% for 0.05s

N/A

Signal ports

2.5kV common, 1kV

differential mode @ 1MHz

3

IEC 61000-4-12

Damped Oscillatory

D.C. Power ports

2.5kV common, 1kV

differential mode @ 1MHz

3

Signal ports

30V Continuous, 300V for 1s

4

IEC 61000-4-16

Mains Frequency Voltage

D.C. Power ports

30V Continuous, 300V for 1s

4

IEC 61000-4-17

Ripple on D.C. Power Supply

D.C. Power ports

10%

3

Signal ports

1.5kV AC (Fail-

Safe Relay output)

N/A

IEC 60255-5

Dielectric Strength

D.C. Power ports

1.5kV DC

N/A

Signal ports

5kV (Fail-Safe Relay output)

N/A

IEC 60255-5

H.V. Impulse

D.C. Power ports

5kV

N/A

Table 3.9. RS900GP IEC 61850-3 Type Tests