Raypak MVB 503-2003 User Manual

Page 54

Advertising
background image

54

START-UP CHECKLIST FOR FAN-ASSISTED

RAYPAK PRODUCTS

This start-up checklist is to be completely filled out by the service technician starting up the Raypak Boiler or Heater
for the first time. All information may be used for warranty purposes and to ensure that the installation is correct.
Additionally this form will be used to record all equipment operation functions and required settings.

GAS SUPPLY DATA

CLEARANCES

Regulator Model & Size

_________ / ______CFH

Front Clearance

_______________In.

Gas Line Size (in room)

________________In. NPT

Right Side Clearance

_______________In.

Length of Gas Line

________________Eq Ft

Left Side Clearance

_______________In.

Low Gas Pressure Setting

________________In. WC

Rear Clearance

_______________In.

High Gas Pressure Setting

________________In. WC

Overhead Clearance

_______________In.

Gas Shut-Off Valve Type

________________

( Ball, Lube cock)

ELECTRICAL

Sediment Trap

________________Y/N

Voltage Supply (VAC)

No Load______ Load_____

Port _______Std______Full

Voltage -24 VAC

_______________VAC

Voltage Com to Ground

_______________VAC

VISUAL INSPECTION OF COMPONENTS

Verify inspection was done and condition of components are in
good working order with a “yes”

Hot Surface Igniter
Auto High Limit Setting
Manual Reset High Limit Setting

_______________Ohms
_______________deg F
_______________deg F

Wiring Harness

_________________ Y/N

Operating Control Setting

_______________deg F

Burner/s (flame)

_________________ Y/N

Refractory (visual)

_________________ Y/N

Sketch plumbing on reverse side

Remote flame sense

_________________ Y/N

WATER SUPPLY

Covers in place for outdoor

_________________ Y/N

Flow Rate in GPM or Delta T

_______________If Avail

Measure flow rate at full fire

VENTING

Pump

Economaster setting

_______________Minutes

Vent Size: _____________

Stack Height:_______

Low Water Cutoff

_______________Test

Category: _________

sketch vent on reverse side *** Number of Tanks and Size

Qty____ _______Gallons

Vent Material:

__________________

Plumbing Size

_______________

Vent Termination Type:

__________________

Pump Size: _________

(boiler)

Pump HP: ______

Combustion Air Openings:

Low __________ in2

Impeller trim____________

Pump Model___________

Ventilation air

High __________ in2

Louvers __________________

Screens________________

EMISSIONS SETTINGS AND TEST INFORMATION

(AT FULL FIRE)

Nominal Factory Recommended Settings

Blower Pressure Setting

_________________In. WC

See manual or card tag

Supply Gas Pressure
Verify stable pressure static &

_________________In. WC
dynamic condition

See manual or card tag

Pilot Gas Pressure

_________________In. WC

See manual or card tag

Manifold Gas Pressure

_________________In. WC

See manual or card tag


The following measurements must be obtained with a Combustion Analyzer.

NOX _________________PPM

Less than 20 PPM (If required by Certifying Agency)

Free Oxygen

_________________%

See manual

CO _________________PPM

Less than 150 PPM

CO2 _________________%

See

manual


Model Number: ______________________________

Serial Number: _______________________________

*** Note: draw venting with details, such as extractors,
barometric dampers, blast dampers or draft inducers

Site Altitude Above Sea Level __________________Ft.

Job Name _______________________________________________________________________________________

Address _________________________________________________________________________________________

Physical Location of Boiler: Indoors______; Outdoors______; Ground Level______; Roof______; Below Grade______

Mechanical Contractor / Installer _______________________________________________________________________

Date and Time of Start-up _____________Print Name and Signature of Start-up Technician_________________________

Information must be faxed to: (805) 278-5471 in order to ensure warranty consideration Attn: Service Manager

Advertising