11

Extending the power cable

12 V systems - Maximum permissible length for extending a power cable (m)

Inter-unit

cable type

Display

type

Power cable core (each core)

mm

2

AWG

1.5

16

2.0

15

2.5

14

4.0

11

6.0

10

10

7

Radome size (ins)

18

24

18

24

18

24

18

24

18

24

18

24

10 m light

C-Series

(6.0)

N/A

(7.0)

N/A

(9.0)

N/A

18.0

N/A

24.0

N/A

47.0

N/A

E-Series

(2.0)

N/A

(3.0)

N/A

(3.0)

N/A

7.0

N/A

9.0

N/A

18.0

N/A

10 m light +

5 m ext

C-Series

(4.0)

N/A

(5.0)

N/A

(6.0)

N/A

12.0

N/A

16.0

N/A

31.0

N/A

E-Series

(2.0)

N/A

(2.0)

N/A

(3.0)

N/A

6.0

N/A

8.0

N/A

16.0

N/A

10 m light +
10 m ext

C-Series

(1.0)

N/A

(2.0)

N/A

(2.0)

N/A

5.0

N/A

6.0

N/A

13.0

N/A

E-Series

DO NOT EXTEND THE POWER CABLE

15 m light

C-Series

(3.0)

N/A

(3.0)

N/A

(4.0)

N/A

9.0

N/A

11.0

N/A

23.0

N/A

E-Series

(1.0)

N/A

(2.0)

N/A

(2.0)

N/A

5.0

N/A

6.0

N/A

13.0

N/A

15 m heavy

C-Series

(6.0)

(4.0)

(8.0)

(6.0)

(11.0)

(7.0)

21.0

14.0

27.0

19.0

50.0

37.0

E-Series

(2.0)

(1.0)

(3.0)

(2.0)

(4.0)

(2.0)

8.0

5.0

10.0

7.0

20.0

14.0