Roberts Gorden CRV-B-4 User Manual

Page 13

Advertising
background image

SECTION 3: C

LEARANCES

TO

C

OMBUSTIBLES

7

NOTE:

1. All dimensions are from the surfaces of all tubes, couplings, elbows, tees and crosses.
2. Clearances B, C and D can be reduced by 50% after 25' (7.5 m) of tubing downstream from

where the combustion chamber and the tube connect.

FIGURE 5: UNIVERSAL SHIELD, POSITION 1

(inches)

(centimeters)

Model

A

B

C

D

A

B

C

D

CRV-B-2

4

12

12

12

11

31

31

31

CRV-B-4

4

12

12

12

11

31

31

31

CRV-B-6

4

12

12

12

11

31

31

31

CRV-B-8

4

12

12

12

11

31

31

31

CRV-B-9

8

18

24

18

21

46

61

46

CRV-B-10

8

18

24

18

21

46

61

46

CRV-B-12

8

18

24

18

21

46

61

46

CRV-B-12A

8

18

24

18

21

46

61

46

C

A

B

D

FIGURE 6: UNIVERSAL SHIELD, POSITION 2

(inches)

(centimeters)

Model

A

B

C

D

A

B

C

D

CRV-B-2

4

24

48

24

11

61

122

61

CRV-B-4

4

24

48

24

11

61

122

61

CRV-B-6

4

24

48

24

11

61

122

61

CRV-B-8

4

24

48

24

11

61

122

61

CRV-B-9

4

36

48

36

11

92

122

92

CRV-B-10

4

36

48

36

11

92

122

92

CRV-B-12

4

36

48

36

11

92

122

92

CRV-B-12A

4

36

48

36

11

92

122

92

C

A

B

D

FIGURE 7: UNIVERSAL SHIELD, POSITION 3

(inches)

(centimeters)

Model

A

B

C

D

A

B

C

D

CRV-B-2

4

12

56

30

11

31

143

77

CRV-B-4

4

12

56

30

11

31

143

77

CRV-B-6

4

12

56

30

11

31

143

77

CRV-B-8

4

12

56

30

11

31

143

77

CRV-B-9

8

12

60

42

21

31

153

107

CRV-B-10

8

12

60

42

21

31

153

107

CRV-B-12

8

12

60

42

21

31

153

107

CRV-B-12A

8

12

60

42

21

31

153

107

C

A

B

D

Advertising
This manual is related to the following products: